Toro 12 Manual de usuario

Busca en linea o descarga Manual de usuario para No Toro 12. Toro 12 User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 88
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Intelli-Sense
Users Guide
TIS3348A 4/23/07 3:12 PM Page i
Professional Controllers
12-, 24-, 36-, and 48-Station Models
TIS-PRO
Vista de pagina 0
1 2 3 4 5 6 ... 87 88

Indice de contenidos

Pagina 1 - User’s Guide

Intelli-SenseUser’s GuideTIS3348A 4/23/07 3:12 PM Page iProfessional Controllers12-, 24-, 36-, and 48-Station ModelsTIS-PRO

Pagina 2

TIS-PROController Hardware Overview1 - Intelli-Sense Control Module - (See page 6 for details.)3 - Weatherproof External Anatenna - Provides exception

Pagina 3 - Table of Contents

MV/PUMP1 2 3 4 5 6 7 8 9 10 11 12MV/PUMP1 2 3 4 5 6 7 8 9 10 11 12VC/COMVC/COM13 14 15 16 17 18 19 20 21 22 23 24VC/COM37 38 39 40 41 42 43 44 45 4

Pagina 4 - Chapter 4 (continued)

6Control Module Overview16a171615141817a14 - Function dia l - Turn this dial in either direction to selectcontroller setup and operational functions:R

Pagina 5

7ALERTS - Display system problems andoperationalconflicts.FLOW - Set flow meter attributes and operationalpartameters.REPORTS - Access and review stat

Pagina 6

8Notes

Pagina 7 - Introduction

Controller Setup•• Set Time Zone • Set Auto Daylight Savings option• Set Maximum Active Stations• Select Stack or Overlap option• Set Master Valve Typ

Pagina 8

Set Controller Clock2. Turn the Lower Line knob to set the current year.4. Turn the Lower Line knob to set the current month.DATE (YEAR)Feb 24 2008DAT

Pagina 9 - Getting Started

11 1. Within the Setup menu, turn the Upper Line knob to view thefollowing display:2. Turn the Lower Line knob to select your time zone from thefollow

Pagina 10 - Controller Hardware Overview

1.2.Within the Setup menu, turn the Upper Line knob to view thefollowing display:Note: The active station count entered in this step will also determi

Pagina 11

1. Within the Setup menu, turn the Upper Line knob to view thefollowing display:STACK OR OVERLAPStackSelect Stack or Overlap OptionWhen the Stacking o

Pagina 12 - Control Module Overview

iiThe Toro CompanyTechnical Support (877) 345-8676WeatherTRAK®ET Everywhere Subscription & Technical Support(800) 362-8774

Pagina 13

1. Within the Setup menu, turn the Upper Line knob to view thefollowing display:2. Turn the Lower Line knob to select the preferred option.Note: If a

Pagina 14

Set Maximum Backup ET1. Within the Setup menu, turn the Upper Line knob to view thefollowing display:Turn the Lower Line knob to adjust the decimal nu

Pagina 16 - DATE (MONTH)

Chapter 3Set Program Schedule1. Turn the Function dial SCHEDULE to view the following display:Program A is selected by default. The current watering

Pagina 17 - AUTO DAYLIGHT SAVINGS

18SET STARTS/WINDOWS PRG ASkip (Button to View)Set Program Start Start Time and Water Window1. Within the Schedule menu, turn the Upper Line knob to

Pagina 18 - 36 36 36

Repeat the editing procedure used to enter the 1st start timeandwater window.8.19(Button to View)5. Turn the Upper Line knob right to select water win

Pagina 19 - STACK OR OVERLAP

20WATER DAY MODE PRG AOptimized by WeatherTRAKWATER DAY MODE PRG AOdd/Even1. With the Function dial in the SCHEDULE position, turn the Upper L

Pagina 20 - NOT ASSIGNED

Days of WeekBy default, every day is an active watering day. To remove daysfrom the schedule, turn the Upper Line knob to select the dayindicator, the

Pagina 21 - No (Check Fuse Often)

22Days of Week by MonthWATER DAY MODE PGM ADays of Week by MonthJan OK TO WATER ON PGM AS M T W T F S 1. Turn the Lower Line knob to select Days o

Pagina 22

Chapter 4Station Data Setup 23The Station Data function menu consists of several station setup parameters required for automatic operation.Four statio

Pagina 23 - Set Program Schedule

iiiTable of ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Chapter 1 - Getting Started . . . . . . . . . . . . . . .

Pagina 24

Select StationStation Setup Mode: Automated by WeatherTRAKSELECT STATION01Select Station ModeSTATION MODE STA 01Automated by WeatherTRAKSelect Pr

Pagina 25

25Select Water Window OptionUse Water Window STA 01Yes (end time 04:00pm)Select Sprinkler TypeSPKLR TYPESpray Head2. Spray Head is selected by defaul

Pagina 26 - Odd/Even

Set Precipitation Rate2. The default PR value will be displayed for the sprinkler typeselected. The whole number is selected in Part 1. Turn the Lower

Pagina 27

The default efficiency value is displayed for the sprinkler typeselected. To change the value, turn the Lower Line knob to adjust the value from 10 –

Pagina 28

Select Plant TypeWithin the Program menu, turn the Upper Line knob to selectPlant Type.PLANT TYPE STA 01Cool Season Turf (default)2.1

Pagina 30

Set Root DepthWithin the Program menu, turn the Upper Line knob to selectSet Root Depth.SET ROOT DEPTH STA 0106 Inches (default)2.1.2.1.The def

Pagina 31

Select Slope Factor2.• 6 – 8% Grade• Mild 9 – 12% Grade Gentle• 0 – 5% GradeNone/Slight• Moderate 13 – 20% Grade• Steep >20% Grade.SET SLOPE FACTO

Pagina 32 - PRECIP PART 2 STA 01

Completing Station Setup1.2.Turn the Upper Line knob to select Station (01) Complete.STATION 01 COMPLETE32The next station number in sequence will be

Pagina 33

33Select StationSELECT STATION01Note: The Maximum Active Station number defined in Setup,determines station number access.1. Withthe Function dial in

Pagina 34

IVChapter 4 (continued)Select Soil Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Select Plant Type . . . . . . . . . .

Pagina 35

34Select Usable Rainfall USABLE RAINFALL100%2. 100% is selected by default. To decrease the value, turn the Lower Line knob right.1. Turn the Upper Li

Pagina 36 - Sunny All Day

35NUMBER OF CYCLES STA 101 Cycles/Operating Day Select Number of CyclesNote: Selecting 0 cycles will prevent the station from operating during autom

Pagina 37 - None, No Slope Set

361.Set Reference [weekly] ET Value (applies to User With ET mode only)Turn the Upper Line knob to view the following display:The Reference ET is the

Pagina 38 - STATION 01 COMPLETE

Support FunctionsFunction PageREVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38COPY . . . . .

Pagina 39

Using the Review Function(1) Station number 1 is assigned to watering Schedule A. (2) The station will water for 11.9 minutes, one cycle per day.(3

Pagina 40 - 05.0 Minutes

39Flow Data ReviewREVIEW MODEFlow DataVIEW EXCLUDED STATIONSView (No Flow Only)01 02 03 04 05 06 07 08N N N N N N Y Y1. With the Function dia

Pagina 41 - 30 Minutes

Using the Copy FunctionCopying Station Information1. Turn the Function dial to COPY to view the followingdisplay:2. Turn the Upper Line knob to select

Pagina 42 - Jul (If Days by Month)

Restoring STATION Default Settings2. Turn the Upper Line knob to select Copy Station Defaultsas shown in the following example:3. Turn the Lower Lin

Pagina 43 - Chapter 5

Restoring PROGRAM Default Settings42 Important: Restoring the default Program settings erasesand resets all user-defined settings for all progr

Pagina 44 - Station Data

Restoring SETUP Default Settings432. Turn the Upper Line knob to select Copy Setup Defaults.COPY FROM STA 01 TOSTA 02 (Press BUTTON)3.Press and hold

Pagina 45 - • Flow Thresholds (GPM)

vUsing the Reports Function . . . . . . . . . . . . . . . . . . . . . . . . . 53Weekly Stations Report. . . . . . . . . . . . . . . . . . . . . . . .

Pagina 46 - COPYING...DONE!

44Using the % Adjust FunctionADJ WATER AMOUNT STA 01 0% = No ChangeADJ WATER AMOUNT STA 01+05% = More WaterADJUSTWater Amount1. Turn the Functi

Pagina 47

Turn the Lower Line knob to select Day Frequency/Depletionadjustment option.ADJUST DAYS (MAD) STA 01+05% = More Often (45%)ADJUST DAYS (MAD) STA 01

Pagina 48

Using the Alerts FunctionFL - Flow StatusVL - Valve StatusCM - Communication StatusWD - Water Window StatusDY - Water Day StatusHW - Hardware StatusSB

Pagina 49 - (Press Button)

MEASURED FLOW (GPM)FM1: 000.0FLOW METER MODEOffFLOW METER MODE147Using the Flow Monitor Function1. Turn the Function dial to the FLOWposition. The Mea

Pagina 50 - Using the % Adjust Function

48EDIT EXCLUDED STATIONSSkip (No Flow Only)01 02 03 04 05 06 07 08 N N N N N N N N 2. Turn the Lower Line knob to change Skip to Edit.2. Turn

Pagina 51

49A default flow sensor K value, based on the flow sensor size, is automatically entered. Refer to the manufacturer’s recommendedK value and edit acco

Pagina 52 - Using the Alerts Function

50HIGH FLOW THRESHOLD050 GPM 3 MinutesSet Threshold and Delay ValuesSetting the High Flow ThresholdThe threshold value is the defined limit for max

Pagina 53

51HIGH FLOW DELAY050 GPM 3 MinutesNO FLOW THRESHOLD005 GPM 3 Minutes3. Turn the Upper Line knob (right) to select High Flow Delay.1. Turn the Uppe

Pagina 54 - Set Flow Meter Size

52LEAK DETECT THRESHOLD015 GPM 3 Minutes1. Turn the Upper Line knob (right) to select Leak Detect Threshold.Setting the Leak Detection ThresholdNote

Pagina 55 - EDIT K VALUE FOR 1:00”

53REPORTS TYPEWeekly StationsWEEKLY RUNTIME STA 01000Hrs 00Mins Since SunUsing the Reports FunctionThe Reports function provides cumulative statio

Pagina 56 - 050 GPM 3 Minutes

viTIS3348A 4/23/07 3:12 PM Page viNotes:

Pagina 57 - Setting the No Flow Threshold

541. Turn the Lower Line knob to select the Flow report option. Flow Report2. Turn the Upper Line knob right on stop to display Todays Usage.3. Turn t

Pagina 58 - LEAK DETECT DELAY

55RAIN PAUSE ALL STATIONS00 Days to ResumeFeb 26 2010 10:15:45am Rain Pause M:Using the Rain Pause FunctionThe Rain Pause function enables a

Pagina 59 - Using the Reports Function

561. Turn the Function dial to the blank position, locatedbetween Flow and Reports.MAINTENANCE TIMEOUTSkip2. Turn the Lower Line dial to Edit.3. Turn

Pagina 60 - Flow Report

CURRENT DAILY ET P0.14 00-00-00 12:00:00Using the ET Function 571. Turn the Function dial to the ET position. The Current Daily ET value recievie

Pagina 61 - Rain Pause M:

58CUSTOM Kc TURF JAN1.00SET WEEKLY ET PART 11.001. With the Function dial in the ET position, turn the Upper Line dial right to select the Cus

Pagina 62 - MAINTENANCE TIMEOUT

59FOR CUSTOMER SERVICEDial 1-800-664-4740Using the Help/Information FunctionHelp and Information Screen OverveiwSet Audible Message AlertBEEP ON MESSA

Pagina 63 - Using the ET Function

Rain Service60The Rain Service feature is offered by WeatherTRAK to monitor rainfallwithin your location and terminate automatic watering in the event

Pagina 64 - SET WEEKLY ET PART 1

CURRENT DEPLETIONSta 01:00% MAD:50%Current DepletionRun Valve TestRUN VALVE TESTSkip01 02 03 04 05 06 07 08-- -- -- -- -- -- -- --PassThe valve test

Pagina 65 - BEEP ON MESSAGE

Manually Operate Specific Stations1. T2. Turn the Upper Line knob to change the station number.urn the Function dial to the MANUAL position. Specific

Pagina 66

Manually Operate All Stations1. T2. Turn the Lower Line knob to view the following display:urn the Function Selector knob to MANUAL.MANUAL WATERAll St

Pagina 67

• Reliable Toro-built irrigation controller.• WeatherTRAK’s exclusive irrigation scheduleing software.•• Four independent irrigation programs• Integra

Pagina 68

64The Run FunctionThe Off FunctionAug 08 2007 10:58:42amON A:02 B: U: M:Aug 08 2007 10:58:42amON A: B: U: M:02Aug 08 2007 10:58:4

Pagina 69

65Troubleshooting GuideAppendix A1. Turn the Function dial to ADJUST. .2. Turn the Upper Line knob to select a station.3. Turn Lower Line knob to adju

Pagina 70 - The Off Function

1. Power to the controller has been disconnected, either by a blown fuseor at the AC power source circuit breaker panel. Check fuse condition,referrin

Pagina 71 - Appendix A

1. The days prior to installation will not be shown in the Week 1schedule. The controller shows what days have irrigated or itanticipates what days wi

Pagina 72

68Notes

Pagina 73

Glossary of TermsGroup Number – This is a code number provided by the ET Everywhereservice to the Intelli-Sense controller at the time of activation.

Pagina 74

Phase Lock – The Intelli-Sense receives daily weather updates fromthree different paging carriers. At the time of ET Everywhere serviceactivation, the

Pagina 75 - Appendix B

71Selecting the Installation Site• Line-of-sightIf possible locate the controller where a majority of the landscape can be viewed from one location. •

Pagina 76

72Mounting the Controller1. Open the cabinet door and TM mounting plate. Position the controller on the wall and mark the top mounting hole location.2

Pagina 77 - Appendix C

73Connecting the Power Wires WARNING: All electrical components must meet applicable national and local electrical codes including installatio

Pagina 78

How the ET Everywhere Service Works2 - Proven scientific modeling techniques are then used tocalculate and validate specific ET data down to one squar

Pagina 79 - Connecting the Power Wires

MV/PUMP1 2 3 4 5 6 7 8 9 10 11 12MV/PUMP1 2 3 4 5 6 7 8 9 10 11 12VC/COMVC/COM13 14 15 16 17 18 19 20 21 22 23 24VC/COM37 38 39 40 41 42 43 44 45 4

Pagina 80 - Connecting the Station Wires

75Valve Common WireValve CommonTerminalsMaster Valve or Pump Start Relay (0.5 A max.)Hot Post6. Connect common wire(s) first. To momentarily operate a

Pagina 81

Toro Rain Sensor Connection76Installation of the Toro TWRS rain sensor or TWFRS rain/freeze sensor sensor is recommend for best results. Note: If a ra

Pagina 82 - RainSwitch M:

Flow Sensor Connection77 Important: Refer to the sensor manufacturer’s recommendedcommunication cable size and type. All cable wire splices mustb

Pagina 84

1. Disconnect power to the controller.2. Carefully remove the blown fuse from the PC board.4. Restore power to the controller.SpecificationsMechanicalE

Pagina 86

81The Toro Promise — Limited Five-Year WarrantyThe Toro Company and its affiliate, Toro Warranty Company,pursuant to an agreement between them, jointl

Pagina 87

www.toro.com© 2009 The Toro Company, Irrigation Division Form Number 373-0547 Rev. BIndustrial Canada compliance informationThis device complies w

Pagina 88

The following checklist provides the basic steps required forIntelli-Sense Professional Controller installation, setup,programming and operation.Thoro

Comentarios a estos manuales

Sin comentarios